{"id":5844,"date":"2016-01-18T13:23:44","date_gmt":"2016-01-18T13:23:44","guid":{"rendered":"https:\/\/mycor.iam.inrae.fr\/IAM\/?page_id=5844"},"modified":"2019-12-03T15:02:04","modified_gmt":"2019-12-03T15:02:04","slug":"protein-engineering","status":"publish","type":"page","link":"https:\/\/mycor.iam.inrae.fr\/IAM\/?page_id=5844","title":{"rendered":"Plateau technique Ing\u00e9nierie prot\u00e9ique (PPE)"},"content":{"rendered":"<h1>Plateau Technique d&#8217;Ing\u00e9nierie Prot\u00e9ique&nbsp;(PPE) \u2013 UMR INRA-UL 1136 IAM<a href=\"https:\/\/mycor.iam.inrae.fr\/IAM\/?page_id=6140\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-1697 alignright\" src=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2013\/06\/grande_bretagne_1606-150x150.gif\" alt=\"grande_bretagne_1606\" width=\"23\" height=\"23\"><\/a><br \/>\nResponsable : Tiphaine DHALLEINE<\/h1>\n<p>La plateforme d&#8217;ing\u00e9nierie Prot\u00e9ique, vise \u00e0 comprendre la relation entre la structure tridimensionnelle des prot\u00e9ines et leurs fonctions, afin de d\u00e9terminer leur r\u00f4le dans la cellule vivante. Des prot\u00e9ines recombinantes peuvent \u00eatre produites et purifi\u00e9es afin d\u2019\u00e9tudier leurs propri\u00e9t\u00e9s physico-chimiques, leur m\u00e9canisme d\u2019action enzymatique ainsi que les interactions avec diff\u00e9rents ligands. La localisation in cellulo des prot\u00e9ines peut \u00e9galement \u00eatre \u00e9tudi\u00e9e au sein de ce plateau.<\/p>\n<p><a href=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Platform-Protein-Engineering.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-6362\" src=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Platform-Protein-Engineering.jpg\" alt=\"Platform Protein Engineering\" width=\"960\" height=\"720\"><\/a><\/p>\n<ul>\n<li><strong>Description des \u00e9quipements :<\/strong><\/li>\n<\/ul>\n<p>Stations chromatographiques FPLC (\u00c4KTA-Purifier, GE Healthcare) et HPLC (UFLC, Shimadzu)<\/p>\n<p style=\"text-align: justify;\">La <strong>FPLC<\/strong> (Fast Protein Liquid Chromatography) est une technologie de chromatographie liquide moyenne pression semi-automatis\u00e9e. L\u2019\u00c4KTA-Purifier est \u00e9quip\u00e9 de pompes \u00e0 <strong><a href=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-full wp-image-6032 alignright\" src=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image1.jpg\" alt=\"Image1\" width=\"172\" height=\"227\"><\/a><\/strong>pistons, d\u2019un d\u00e9tecteur UV \u00e0 longueur d\u2019onde variable et d\u2019un collecteur de fractions. Les colonnes actuellement disponibles sur le plateau sont des colonnes analytiques d\u2019exclusion st\u00e9rique Superdex 75 10\/300 et Superdex 200 10\/300 et les colonnes pr\u00e9paratives correspondantes Superdex 75 16\/600 et Superdex 200 16\/600. D\u2019autres colonnes pour la ch\u00e9lation sur m\u00e9tal immobilis\u00e9, les colonnes HisTrap 1 et 5 mL, peuvent \u00e9galement \u00eatre connect\u00e9es sur l\u2019\u00c4KTA-Purifier. L\u2019appareillage, install\u00e9 dans une enceinte r\u00e9frig\u00e9r\u00e9e \u00e0 4\u00b0C, est pilot\u00e9 par le logiciel Unicorn 5.2 (GE Healthcare).<\/p>\n<p style=\"text-align: justify;\"><a href=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-full wp-image-6033 alignleft\" src=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image2.jpg\" alt=\"Image2\" width=\"252\" height=\"189\"><\/a><\/p>\n<p style=\"text-align: justify;\">L\u2019<strong>HPLC<\/strong> (High Performance Liquid Chromatography) est une technologie de chromatographie liquide haute pression automatis\u00e9e. L\u2019UFLC est \u00e9quip\u00e9 de pompes \u00e0 pistons, d\u2019un injecteur automatique d\u2019\u00e9chantillons, d\u2019un collecteur de fractions, d\u2019un four pour colonne et de deux d\u00e9tecteurs : un d\u00e9tecteur UV-visible \u00e0 longueur d\u2019onde variable et un d\u00e9tecteur \u00e0 barrette de diodes permettant d\u2019analyser les spectres UV-visibles des constituants chromatographi\u00e9s. Les colonnes actuellement disponibles sur le plateau sont des colonnes de phase invers\u00e9es analytiques Gemini C18 5 \u00b5m 150 x 3 mm, Kinetex Biphenyl 5 \u00b5m 250 x 4,6 mm, Kinetex C18 2,6 \u00b5m 100 x 4,6 mm, Jupiter C18 5 \u00b5m 250 x 4,6 mm et les colonnes pr\u00e9paratives correspondantes Gemini C18 5 \u00b5m 250 x 10 mm, Kinetex Biphenyl 5 \u00b5m 250 x 10 mm. Une colonne d\u2019exclusion st\u00e9rique, BioSep-SEC S3000300 x 7,8 mm, peut \u00e9galement \u00eatre connect\u00e9e sur l\u2019HPLC. L\u2019appareillage UFLC est pilot\u00e9 avec le logiciel LC-LabSolutions (Shimadzu).<\/p>\n<p style=\"text-align: justify;\"><strong>Bo\u00eete \u00e0 gants (GP[Concept], Jacomex)<\/strong><a href=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-full wp-image-6034 alignright\" src=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image3.jpg\" alt=\"Image3\" width=\"278\" height=\"211\"><\/a><br \/>\nLa bo\u00eete \u00e0 gants est une enceinte \u00e9tanche qui permet de manipuler dans une atmosph\u00e8re sous azote, en absence d\u2019oxyg\u00e8ne. Des gants, fix\u00e9s \u00e0 une des parois, permettent d&#8217;acc\u00e9der \u00e0 l&#8217;int\u00e9rieur sans que le confinement cesse. Des SAS d\u2019entr\u00e9e-sortie, de capacit\u00e9s diff\u00e9rentes, permettent les \u00e9changes avec l\u2019ext\u00e9rieur.<\/p>\n<p style=\"text-align: justify;\"><strong>Appareils de fluorim\u00e9trie CaryEclipse (Varian) et lecteur de microplaque Victor X5 (Perkin Elmer).<\/strong><br \/>\nLe spectrophotom\u00e8tre \u00e0 fluorescence CaryEclipse permet de d\u00e9terminer la concentration de certains compos\u00e9s<strong><a href=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image4.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"  wp-image-6035 alignleft\" src=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image4.jpg\" alt=\"Image4\" width=\"227\" height=\"174\"><\/a><\/strong> fluorescents et de suivre des cin\u00e9tiques enzymatiques dans une gamme de 200 \u00e0 900 nm. Cet instrument poss\u00e8de une lampe \u00e0 x\u00e9non. Il est contr\u00f4l\u00e9 par le logiciel CaryEclipse ADL Shell Application (Varian).<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: justify;\"><strong>Le lecteur Victor X5<\/strong> est un lecteur de microplaque dont la d\u00e9tection est bas\u00e9e sur <a href=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image5.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" size-full wp-image-6036 alignright\" src=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image5.jpg\" alt=\"Image5\" width=\"252\" height=\"188\"><\/a>l&#8217;\u00e9mission et l&#8217;absorption de lumi\u00e8re, comprenant la luminescence, la fluorescence, l&#8217;absorbance (visible et UV), la fluorescence en temps r\u00e9solu et la fluorescence polaris\u00e9e. Une roue porte diff\u00e9rents filtres d\u2019excitation et d\u2019\u00e9mission permettant de s\u00e9lectionner une longueur d\u2019onde d\u2019int\u00e9r\u00eat. Le lecteur est pilot\u00e9 avec le logiciel Perkin-Elmer 2030 4.00.<\/p>\n<p>&nbsp;<a href=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image6.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"  wp-image-6037 alignleft\" src=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image6.jpg\" alt=\"Image6\" width=\"185\" height=\"140\"><\/a><strong>Analyseur d\u2019images Odyssey (Li-COR)<\/strong><\/p>\n<p>Le scanner Odyssey est un syst\u00e8me d&#8217;imagerie dans l&#8217;infrarouge et le proche infrarouge qui permet d&#8217;analyser des gels de prot\u00e9ines, d&#8217;ADN et des Western-Blot. L\u2019appareil est pilot\u00e9 avec le logiciel Odyssey 3.0 (LI-COR).<\/p>\n<p style=\"text-align: justify;\"><strong>Calorim\u00e9trie \u00e0 titrage isotherme (MicroCal ITC200, GE Healthcare)<br \/>\n<\/strong>Le syst\u00e8me de titrage calorim\u00e9trique isotherme (ITC) MicroCal ITC200 est utilis\u00e9 pour \u00e9tudier une large gamme d&#8217;interactions entre des biomol\u00e9cules. Cet app<a href=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image7.png\"><img loading=\"lazy\" decoding=\"async\" class=\" size-full wp-image-6038 alignright\" src=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image7.png\" alt=\"Image7\" width=\"170\" height=\"226\"><\/a>areillage permet des mesures directes, sans marquage et en solution, de l&#8217;affinit\u00e9 de liaison, de la st\u0153chiom\u00e9trie et des param\u00e8tres thermodynamiques de l\u2019interaction entre deux compos\u00e9s, en une unique exp\u00e9rience. Un de deux compos\u00e9s est plac\u00e9 dans une cellule dont la temp\u00e9rature est r\u00e9gul\u00e9e tandis que l\u2019autre compos\u00e9 est pr\u00e9lev\u00e9 avec une seringue motoris\u00e9e et inject\u00e9 en plusieurs volumes successifs dans la cellule sous agitation. La mesure de la chaleur d\u00e9gag\u00e9e (r\u00e9action exothermique) ou capt\u00e9e (r\u00e9action endothermique) lors de l\u2019interaction permet de caract\u00e9riser la thermodynamique du syst\u00e8me. Le syst\u00e8me est contr\u00f4l\u00e9 par le logicielMicroCal ITC200.<\/p>\n<p><strong>&nbsp;Microscopie \u00e0 fluorescence <a href=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image8.png\"><img loading=\"lazy\" decoding=\"async\" class=\" size-full wp-image-6039 alignleft\" src=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image8.png\" alt=\"Image8\" width=\"278\" height=\"210\"><\/a>(microscope invers\u00e9 Axio Vert A1, ZEISS)<\/strong><\/p>\n<p style=\"text-align: justify;\">Le microscope invers\u00e9 Axio Vert A1 est un microscope \u00e0 fluorescence LED (lumi\u00e8re transmise entre 400 et 700 nm) pour l\u2019observation de cellules gr\u00e2ce aux diff\u00e9rentes techniques de contraste qui peuvent \u00eatre mise en \u0153uvre. L\u2019appareil est \u00e9quip\u00e9 d\u2019une cam\u00e9ra Jenoptik ProgGres et le syst\u00e8me est contr\u00f4l\u00e9 par le logiciel ProgRes CapturePro 2.8.8 (ZEISS).<\/p>\n<ul>\n<li style=\"text-align: justify;\"><strong>Modalit\u00e9s d\u2019utilisation des \u00e9quipements :<\/strong><\/li>\n<\/ul>\n<p>Le plateau PPE est accessible du lundi au vendredi sur rendez-vous aupr\u00e8s de la responsable. Il est localis\u00e9 au sein de l\u2019UMR 1136 (entr\u00e9e 1B, niveau 3) \u00e0 la Facult\u00e9 des Sciences et Technologies \u00e0 Vand\u0153uvre-l\u00e8s-Nancy.<\/p>\n<p><strong>Responsable du plateau PPE&nbsp;:<a href=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image9.png\"><img loading=\"lazy\" decoding=\"async\" class=\" size-full wp-image-6040 alignright\" src=\"https:\/\/mycor.iam.inrae.fr\/IAM\/wp-content\/uploads\/2016\/01\/Image9.png\" alt=\"Image9\" width=\"122\" height=\"153\"><\/a><\/strong><br \/>\nTiphaine DHALLEINE, Ing\u00e9nieur d\u2019\u00c9tudes, UMR INRA-UL 1136 IAM, Facult\u00e9 des Sciences et Technologies UL, 54500 Vand\u0153uvre-l\u00e8s-Nancy, Tel 03 83 68 42 27, E-mail : tiphaine.dhalleine@univ-lorraine.fr<\/p>\n<p style=\"text-align: justify;\"><strong>Activit\u00e9s :<\/strong><br \/>\n<em>Appareils de chromatographies FPLC (\u00c4KTA-Purifier, GE Healthcare) et HPLC (UFLC, Shimadzu)<\/em><br \/>\nLa FPLC permet de purifier les prot\u00e9ines soit en fonction de la taille par chromatographie d\u2019exclusion st\u00e9rique (SEC), soit en fixant leur Tag Histidine sur nickel immobilis\u00e9 sur une r\u00e9sine (IMAC), ou encore en fonction de leur \u00e9tat de charge par \u00e9change d\u2019ions (IEC).<br \/>\nLa technologie HPLC a plut\u00f4t vocation \u00e0 doser et \u00e0 purifier des petites mol\u00e9cules telles que les extractibles de plantes et les produits de r\u00e9actions enzymatiques sur colonne de phase invers\u00e9e (RP-HPLC).<\/p>\n<p style=\"text-align: justify;\"><em>Bo\u00eete \u00e0 gants (GP[Concept], Jacomex)<\/em><br \/>\nLa bo\u00eete \u00e0 gants permet de manipuler sous azote, dans une atmosph\u00e8re exempte d\u2019oxyg\u00e8ne, afin de pr\u00e9server certaines prot\u00e9ines s\u2019oxydant spontan\u00e9ment \u00e0 l\u2019air (telles que les prot\u00e9ines \u00e0 centre fer-soufre et certaines enzymes d\u2019oxydo-r\u00e9duction).<\/p>\n<p style=\"text-align: justify;\"><em>Appareils de fluorim\u00e9trie CaryEclipse (Varian) et lecteur de microplaque Victor X5 (Perkin Elmer)<\/em><br \/>\nCes syst\u00e8mes sont utilis\u00e9s pour le dosage de prot\u00e9ines fluorescentes (marqu\u00e9es par une sonde telle que l\u2019ANS, ou conjugu\u00e9es \u00e0 la GFP ou \u00e0 la mCherry). Ils permettent \u00e9galement de r\u00e9aliser des tests d\u2019activit\u00e9 enzymatique. Le syst\u00e8me Victor, qui permet la lecture de microplaques, est adapt\u00e9 pour l\u2019analyse d\u2019un grand nombre d\u2019\u00e9chantillons.<\/p>\n<p style=\"text-align: justify;\"><em>Analyseur d\u2019images Odyssey (Li-COR)<\/em><br \/>\nLes applications possibles sur l&#8217;Odyssey sont multiples. Outre les traditionnelles visualisations de Western-blot sur membrane PVDF ou nitrocellulose, cet appareil permet la visualisation et la quantification des marquages (simples ou doubles) directement sur gel (In-Gel Western-blot).<\/p>\n<p style=\"text-align: justify;\"><em>Calorim\u00e9trie \u00e0 titrage isotherme (MicroCal ITC200, GE Healthcare)<\/em><br \/>\nCe syst\u00e8me permet de d\u00e9terminer les param\u00e8tres d\u2019affinit\u00e9 de l\u2019interaction entre deux compos\u00e9s (prot\u00e9ines-prot\u00e9ines, prot\u00e9ines-ions m\u00e9talliques, prot\u00e9ines-petites mol\u00e9cules, etc.) tels que la constante de dissociation (Kd), la st\u0153chiom\u00e9trie de r\u00e9action (n) ainsi que les param\u00e8tres thermodynamique de la r\u00e9action tels que l\u2019enthalpie (\u2206H), l\u2019\u00e9nergie libre de Gibbs (\u2206G), et l\u2019entropie (\u2206S). Ces param\u00e8tres renseignent sur la nature chimique de l\u2019interaction (liaisons de Van der Waals, liaisons hydrog\u00e8ne, liaisons hydrophobes et d\u00e9solvatation).<\/p>\n<p style=\"text-align: justify;\"><em>Microscopie \u00e0 fluorescence (microscope invers\u00e9 Axio Vert A1, ZEISS)<\/em><br \/>\nLa microscopie \u00e0 fluorescence permet de d\u00e9tecter et de localiser une prot\u00e9ine fluorescente dans une cellule vivante transform\u00e9e ou dans un extrait v\u00e9g\u00e9tal marqu\u00e9 et de la quantifier \u00e9ventuellement.<\/p>\n<p><strong>Missions :<\/strong><\/p>\n<p style=\"text-align: justify;\">Mettre \u00e0 disposition des chercheurs partenaires, les \u00e9quipements du plateau PPE et l\u2019expertise m\u00e9thodologique n\u00e9cessaire au d\u00e9veloppement des projets.<br \/>\nContribuer au rayonnement scientifique de l\u2019unit\u00e9 de recherche en r\u00e9pondant aux besoins des collaborations scientifiques engag\u00e9es.<br \/>\nInt\u00e9grer des r\u00e9seaux d\u2019utilisateurs et d\u00e9velopper des interactions avec d\u2019autres plateaux technologiques afin d\u2019enrichir l\u2019expertise et de rem\u00e9dier aux probl\u00e8mes techniques rencontr\u00e9s. Faire de la veille technologique et pr\u00e9voir les investissements futurs.<\/p>\n<p style=\"text-align: justify;\"><strong>Sp\u00e9cificit\u00e9s :<\/strong><\/p>\n<p style=\"text-align: justify;\">Le plateau PPE est int\u00e9gr\u00e9 dans l\u2019\u00e9quipe Redox de l\u2019UMR INRA-UL 1136 IAM localis\u00e9e \u00e0 la facult\u00e9 des sciences et technologies de l\u2019UL, \u00e0 Vand\u0153uvre-l\u00e8s-Nancy.<br \/>\nL\u2019Unit\u00e9 de Recherche IAM fait partie du p\u00f4le scientifique A2F (Agronomie, Agroalimentaire &amp; For\u00eat) qui regroupe six laboratoires de recherche f\u00e9d\u00e9r\u00e9s au sein de l\u2019institut f\u00e9d\u00e9ratif EFABA (Ecosyst\u00e8mes Forestiers, Agroressources, Biomol\u00e9cules et Alimentation). Le p\u00f4le A2F s\u2019appuie sur des associations fortes avec l\u2019INRA et un partenariat avec AgroParisTech. Les deux axes majeurs du secteur sont d\u2019une part la for\u00eat et le bois et d\u2019autre part l\u2019agronomie et l\u2019agroalimentaire. Ces axes se retrouvent dans un p\u00f4le de comp\u00e9tence du minist\u00e8re de l\u2019agriculture et de la p\u00eache et du minist\u00e8re de l\u2019enseignement sup\u00e9rieur et de la recherche, intitul\u00e9 FABELOR (For\u00eat \u2013 Agroalimentaire \u2013 biotechnologie \u2013 Environnement en Lorraine). La partie For\u00eat Bois est structur\u00e9e autour du laboratoire d\u2019excellence ARBRE (LabEx ARBRE).<br \/>\nLe plateau PPE interagira fortement avec la future plateforme ASIA (Approches fonctionnelles et Structurales des InterActions cellulaires) soutenue par les laboratoires du p\u00f4le A2F localis\u00e9s \u00e0 la facult\u00e9 des sciences et techniques.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Plateau Technique d&#8217;Ing\u00e9nierie Prot\u00e9ique&nbsp;(PPE) \u2013 UMR INRA-UL 1136 IAM Responsable : Tiphaine DHALLEINE La plateforme d&#8217;ing\u00e9nierie Prot\u00e9ique, vise \u00e0 comprendre la relation entre la structure tridimensionnelle des prot\u00e9ines et leurs fonctions, afin de d\u00e9terminer leur r\u00f4le dans la cellule vivante. &hellip; <a href=\"https:\/\/mycor.iam.inrae.fr\/IAM\/?page_id=5844\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":7,"featured_media":0,"parent":5862,"menu_order":0,"comment_status":"closed","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-5844","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/mycor.iam.inrae.fr\/IAM\/index.php?rest_route=\/wp\/v2\/pages\/5844","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mycor.iam.inrae.fr\/IAM\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mycor.iam.inrae.fr\/IAM\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mycor.iam.inrae.fr\/IAM\/index.php?rest_route=\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/mycor.iam.inrae.fr\/IAM\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5844"}],"version-history":[{"count":0,"href":"https:\/\/mycor.iam.inrae.fr\/IAM\/index.php?rest_route=\/wp\/v2\/pages\/5844\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/mycor.iam.inrae.fr\/IAM\/index.php?rest_route=\/wp\/v2\/pages\/5862"}],"wp:attachment":[{"href":"https:\/\/mycor.iam.inrae.fr\/IAM\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5844"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}